ZS Pro-F

The Automated Logic® ZS room sensors are an integral component of the WebCTRL® building automation system. These sensors provide the function and flexibility you need to manage the conditions important to the comfort, productivity, and sustainability of your facility, and are designed to work with ZN, SE, and ME line controllers.

Refer to the attached Spec Sheet for ZS Pro-F features. 

Specifications
Sensing Element Range Accuracy
Temperature with any Option (excluding Humidity) -4° to 122° F (-20° C to 50° C) ±0.35° F (0.2° C)
Temperature with Humidity and any Option 50° F to 104° F (10° C to 40° C) ±0.5° F (0.3° C)
Humidity 20% to 80% ±2% typical
CO2 400 to 1250 PPM
1250 to 2000 PPM
±30PPM or +/-3% (greater of two)
±5% of reading plus 30 PPM
VOC 0 to 2,000 PPM ±100 PPM
Motion Sensing Sensor Type: PIR
Distance: 16.4 feet, (5 m)
Detection range: (HxV) 100° x 82°
Movement speed: 2.62 to 3.94 ft/s (0.8 to 1.2 m/s)
Detection object: 27.56 x 9.84 in. (700 x 250 mm)
Power Requirements Sensor Type Power Required
Temperature Only
Temperature with Humidity
All Models 12 Vdc @ 8 mA
Temp with VOC, or Temp/VOC/Humidity All Models 12 Vdc @ 60 mA
Temp with CO2 , or Temp/ CO2 /Humidity All Models 12 Vdc @ 15 mA (idle) to 190 mA
(CO2 measurement cycle)
Power Supply A controller supplies the Rnet sensor network with 12 Vdc @ 210 mA.
Additional power may be required. See sensor power requirements above.
Communication 115 kbps Rnet connection between sensor(s) and controller
15 sensors max per Rnet network; 5 sensors max per control program
Local Access Port For connecting a laptop computer to the local equipment or WebCTRL®
network for maintenance and commissioning
Environmental Operating Range 32° to 122° F (0° - 50° C), 10% to 90% relative humidity, non-condensing
Mounting Dimensions Standard 4”x 2” electrical box using provided 6/32” x 1/2” mounting screws
Overall Dimensions Width: 2.75” (6.99 cm)
Height: 4.75” (12.07 cm)
Depth: 13/16” (2.01 cm)
Options & Part Numbers ZS Standard ZS Plus ZS Pro ZS Pro-F ZS Pro-M
Temperature Only ZS2-ALC ZS2PL-ALC ZS2P-ALC ZS2PF-ALC ZS2P-M-ALC
Temp with CO2 ZS2-C-ALC ZS2PL-C-ALC ZS2P-C-ALC ZS2PF-C-ALC ZS2P-CM-ALC
Temp with Humidity ZS2-H-ALC ZS2PL-H-ALC ZS2P-H-ALC ZS2PF-H-ALC ZS2P-HM-ALC
Temp, Humidity, CO2 ZS2-HC-ALC ZS2PL-HC-ALC ZS2P-HC-ALC ZS2PF-HC-ALC ZS2P-HCM-ALC
Temp, IAQ | VOC ZS2-V-BNK ZS2PL-V-BNK - - -
Temp, Humidity, IAQ | VOC ZS2-HV-BNK ZS2PL-HV-BNK - - -
Sensing Element Range Accuracy
Temperature with any Option (excluding Humidity) -4° to 122° F (-20° C to 50° C) ±0.35° F (0.2° C)
Temperature with Humidity and any Option 50° F to 104° F (10° C to 40° C) ±0.5° F (0.3° C)
Humidity 20% to 80% ±2% typical
CO2 400 to 1250 PPM
1250 to 2000 PPM
±30PPM or +/-3% (greater of two)
±5% of reading plus 30 PPM
VOC 0 to 2,000 PPM ±100 PPM
Motion Sensing Sensor Type: PIR
Distance: 16.4 feet, (5 m)
Detection range: (HxV) 100° x 82°
Movement speed: 2.62 to 3.94 ft/s (0.8 to 1.2 m/s)
Detection object: 27.56 x 9.84 in. (700 x 250 mm)
Power Requirements Sensor Type Power Required
Temperature Only
Temperature with Humidity
All Models 12 Vdc @ 8 mA
Temp with VOC, or Temp/VOC/Humidity All Models 12 Vdc @ 60 mA
Temp with CO2 , or Temp/ CO2 /Humidity All Models 12 Vdc @ 15 mA (idle) to 190 mA
(CO2 measurement cycle)
Power Supply A controller supplies the Rnet sensor network with 12 Vdc @ 210 mA.
Additional power may be required. See sensor power requirements above.
Communication 115 kbps Rnet connection between sensor(s) and controller
15 sensors max per Rnet network; 5 sensors max per control program
Local Access Port For connecting a laptop computer to the local equipment or WebCTRL®
network for maintenance and commissioning
Environmental Operating Range 32° to 122° F (0° - 50° C), 10% to 90% relative humidity, non-condensing
Mounting Dimensions Standard 4”x 2” electrical box using provided 6/32” x 1/2” mounting screws
Overall Dimensions Width: 2.75” (6.99 cm)
Height: 4.75” (12.07 cm)
Depth: 13/16” (2.01 cm)
Options & Part Numbers ZS Standard ZS Plus ZS Pro ZS Pro-F ZS Pro-M
Temperature Only ZS2-ALC ZS2PL-ALC ZS2P-ALC ZS2PF-ALC ZS2P-M-ALC
Temp with CO2 ZS2-C-ALC ZS2PL-C-ALC ZS2P-C-ALC ZS2PF-C-ALC ZS2P-CM-ALC
Temp with Humidity ZS2-H-ALC ZS2PL-H-ALC ZS2P-H-ALC ZS2PF-H-ALC ZS2P-HM-ALC
Temp, Humidity, CO2 ZS2-HC-ALC ZS2PL-HC-ALC ZS2P-HC-ALC ZS2PF-HC-ALC ZS2P-HCM-ALC
Temp, IAQ | VOC ZS2-V-BNK ZS2PL-V-BNK - - -
Temp, Humidity, IAQ | VOC ZS2-HV-BNK ZS2PL-HV-BNK - - -