ZN551 Zone Controller

The ZN551 is a fully programmable, native BACnet Advanced Application Controller (AAC) designed for controlling a single zone in a building. The ZN551 is well suited for VAV, heat pump, unit ventilator and other packaged HVAC applications. It communicates on an EIA-485 LAN using BACnet MS/TP communications and connects seamlessly to the WebCTRL® building automation system.

Application Features
  • Versatile controller suitable for a variety of applications, including fan coil units, lighting, and exhaust fan control
  • Standard library of control programs available for most zoning applications
  • Supports EIKON® graphical programming software, an object-oriented tool that provides complete flexibility for any custom control sequence that you need
  • Supports Automated Logic® communicating sensors, which are available in a variety of zone sensing combinations and support setpoint adjustment and occupancy overrides
  • Supports Automated Logic touchscreen interfaces for managing and troubleshooting the connected equipment easily
  • Supports live, visual displays of control logic, which uses real time operational data and aids in optimizing and troubleshooting system operations
  • Quick & easy test and balancing process
Hardware Features
  • Controls up to 11 points (5 binary outputs, 5 universal inputs and 1 analog output)
  • Supports native BACnet over MS/TP communications when required
  • Fast, powerful, and fully distributed control allows complete independence from any other devices in the system
  • Firmware upgrades can be performed remotely
  • Easy startup and commissioning using the WebCTRL system user interfaces
  • Versatile controller suitable for a variety of applications, including fan coil units, lighting, and exhaust fan control
  • Standard library of control programs available for most zoning applications
  • Supports EIKON® graphical programming software, an object-oriented tool that provides complete flexibility for any custom control sequence that you need
  • Supports Automated Logic® communicating sensors, which are available in a variety of zone sensing combinations and support setpoint adjustment and occupancy overrides
  • Supports Automated Logic touchscreen interfaces for managing and troubleshooting the connected equipment easily
  • Supports live, visual displays of control logic, which uses real time operational data and aids in optimizing and troubleshooting system operations
  • Quick & easy test and balancing process
  • Controls up to 11 points (5 binary outputs, 5 universal inputs and 1 analog output)
  • Supports native BACnet over MS/TP communications when required
  • Fast, powerful, and fully distributed control allows complete independence from any other devices in the system
  • Firmware upgrades can be performed remotely
  • Easy startup and commissioning using the WebCTRL system user interfaces