ACxelerate™ v3.0 Commissioning Tool
ADD-ON FOR THE WEBCTRL® SYSTEM
PART #s: ACX-RENEW-C, ACX-RENEW-CDLR, ADD-ACX, AND ADD-ACX-R
The ACxelerate v3.0 auto-commissioning tool is an add-on for the WebCTRL (v9 or higher) building automation system that automates VAV commissioning workflows, helping reduce the manual effort required to test terminal units. Engineered to accommodate single-duct, dual-duct, and fan-powered (series and parallel) VAV terminal unit dampers and reheat valves, ACxelerate v3.0 has been shown to substantially reduce commissioning time. By reducing commissioning timelines from days or weeks down to hours, the tool helps teams streamline project handovers across a wide range of building applications.1
1Field Demonstration of an Automated Building Commissioning Tool
Automated testing expanded: Now supports fan-powered VAV boxes.
Historical test access: View and re-run prior tests for faster validation.
Smarter equipment discovery: Automatically identifies VAVs and associated AHU/RTU systems.
Improved UI/UX: More intuitive setup and streamlined test execution.
Accelerate Project Commissioning (Dealers & System Integrators)
Helps reduce manual on-site commissioning effort by automatically discovering supported VAV boxes and associated AHU/RTU equipment, and automates functional testing of dampers and reheat valves to ensure proper operation.
Support Performance Validation (Specifiers & Building Owners)
Simplifies performance verification by generating comprehensive reports that document system health, validate operational performance, and maintain a historical record of test results.
Verify System Performance Over Time (Facility Managers)
After initial commissioning, facility teams can use ACxelerate on an ongoing basis to confirm that VAV system performance is maintained over time. Automated analysis and dashboard views highlight areas of concern, helping identify issues that may need follow-up to support comfort and system performance.
Automated testing expanded: Now supports fan-powered VAV boxes.
Historical test access: View and re-run prior tests for faster validation.
Smarter equipment discovery: Automatically identifies VAVs and associated AHU/RTU systems.
Improved UI/UX: More intuitive setup and streamlined test execution.
Accelerate Project Commissioning (Dealers & System Integrators)
Helps reduce manual on-site commissioning effort by automatically discovering supported VAV boxes and associated AHU/RTU equipment, and automates functional testing of dampers and reheat valves to ensure proper operation.
Support Performance Validation (Specifiers & Building Owners)
Simplifies performance verification by generating comprehensive reports that document system health, validate operational performance, and maintain a historical record of test results.
Verify System Performance Over Time (Facility Managers)
After initial commissioning, facility teams can use ACxelerate on an ongoing basis to confirm that VAV system performance is maintained over time. Automated analysis and dashboard views highlight areas of concern, helping identify issues that may need follow-up to support comfort and system performance.