Skip to main content
open-systems open-systems-mb

SYSTEM INTEGRATION

Building efficiency starts with consolidating all your facilities, systems, and equipment for better visibility and greater control, enabling centralized management from a single user interface.

AutomatedLogic-WebCTRL-logo
Enterprise_Icons_background-new
Water
water
hvac
HVAC
Fire
fire
lighting
Lighting
Monitoring
monitoring
energy
Energy
Security
security
elevators
Elevators
Enterprise
enterprise
electricity
Electrical
bg-orange-new
parking-lot-lighting-on-tablet
HARDWARE INTEGRATION SOLUTIONS

Easily integrate third-party sub-systems including lighting, fire, security, and more with our hardware gateways. With support for open protocols including BACnet, Modbus, SNMP, M-Bus, and KNX, along with scalable point packs, these gateways help ensure seamless connection to building systems.

weather-app-on-tablet
SOFTWARE INTEGRATION SOLUTIONS

Our WebCTRL add-ons connect with third party applications for scheduling, single sign on, automated demand response, weather forecasting, and more. These integrations align building operations with business systems—enabling more responsive, efficient, and coordinated performance.

Explore Software Solutions keyboard_arrow_right
bg-gray-pattern-left
energy-usage-on-tablet
OPEN APIs FOR SEAMLESS DATA EXCHANGE

WebCTRL supports secure data exchange through RESTful APIs, Java SDKs, and SOAP/XML Web Services—so external systems can securely query and interact with BAS data without additional hardware.

Count on an authorized Automated logic representative to be your Master Systems Integrator (MSI) and discover the true potential of our solutions.
MSI: YOUR EXPERT INTEGRATION PARTNER

Count on an authorized Automated Logic representative to be your Multiple System Integrator (MSI) and discover the true potential of our solutions. Our MSIs are trained to make sure all your systems are communicating properly and that building stakeholders have access to the information they need.

Integration Expertise

Our MSI experts will help you from start to finish.

man-woman-icon
Consulting

We’ll review your vision, objectives, personas, journeys, and constraints to create the functional requirements and key performance indicators (KPIs). We’ll review enabling technologies, create the statement of work and specification addenda, and evaluate vendors.

tools-icon
Service

We’ll manage software patches and upgrades, system monitoring, fit-outs/remodels, and sub-system changes. We’ll supply a service contract, service projects, a change control protocol, continuing education, and automated reporting.

gear-icon
Execution

We’ll create the manpower, testing, and commissioning plans. We’ll install the control panels, servers, network, and integration platform. We’ll supply as-built documents, verification reports, certification support, system training, warranty letter, and MyWay Building App for occupants.

pen-paper-icon
Design

We’ll create the design submittals, software and graphics, ceiling plan, and server and network layouts. We’ll also develop the change control protocol, commissioning script, installation plan, and risk management framework.

INTEGRATION EXPERIENCE

Our track record includes successful integrations with the following systems and manufacturers.

INTEGRATION CATEGORY EQUIPMENT TYPE COMPATIBLE SYSTEMS

Building Systems

Core building technologies that control the physical environment, safety, and essential operations of the facility.
HVAC Carrier, Trane, York, Lennox, AAON, Daikin, LG, Mitsubishi, Seasons 4, Munters, Addison
Lighting Acuity, Phillips, Lutron, Crestron, Hubbell, Leviton, GE, WattStopper, Enlighted, Triatek, BlueRidge
Dynamic Glass / Shades Sage Glass, View Glass, Draper, Loytec, Mechoshade, Somfy
Fire / Smoke Edwards, Simplex, Vesda, JCI, Hochiki, Kedde-FenwalNet, Notifier, Siemens EV Charging Clipper Creek, ABB, Schneider Electric, GE

Energy & Sustainability

Solutions that monitor, optimize, and manage energy use to improve efficiency, reduce costs, and support sustainability goals.
Energy Monitoring Schneider, EATON, Siemens, Electro Industries, eGuage, GE, Veris, Setra
Demand Response OpenADR 2.0a, OpenADR 2.0b, cPower-VirtuwattLink, Voltus, PG&E, Austin Energy, Enernoc, Joule, SCE
Photovoltaic (PV) Monitoring AlsoEnergy, SolarEdge, Vigilant, SunGrow, SMA
Continuous Commissioning ACxelerate

Workplace Experience & Smart Building Applications

User-focused technologies that enhance occupant comfort, productivity, and interaction with the building through data-driven insights.
Personalized Comfort MyWay, Comfy
Room Scheduling MS Exchange, Crestron, Cisco
Predictive Occupancy Lenel S2 – OnGuard, Cisco CMX, MyWay
Location Services Cisco CMX, Phunware, MyWay
Mobile Credentialing MyWay, Blue Diamond, Supra
Hospital Beds Rego

Security, Operations & Critical Systems

Systems that ensure safety, protect assets, and enable efficient facility operations and mission-critical performance.
Security/Access Control Lenel S2, Onity, Diebold
Centralized Alarming Lenel S2-OnGuard
Service Ticketing Service Max, Maximo, Service Channel, Dude Solutions, SalesForce
Vertical Transportation Otis, Thyssen Krupp
Data Centers Data Centers
bg-orange-left
AutomatedLogic WebCtrl screen capture - generator in basement
AutomatedLogic-WebCTRL-logo
CONNECT ALL YOUR BUILDING SYSTEMS

Explore our full range of integration products.

red-bg-cta-success-stories Red Building Background 1x1
SEE IT ALL FOR YOURSELF!
Contact us to schedule a live demo and experience all the benefits of our intelligent building solutions firsthand.
REQUEST A DEMO person