EIKON® II
Students will expand on knowledge from the EIKON® I course to learn how to create complex control programs and logic symbols. Students will also be able to identify programming as it is implemented within a complete system and will utilize naming standards to create a library for quickly placing previously developed logic into new systems, thus making programming more efficient. Building a properties page, simulating a control program, and major customization to EquipmentBuilder programs are among several other intermediate EIKON features offered in this course.
After successfully completing this course, you will be able to use Automated Logic’s EIKON tool to quickly and efficiently:
Create basic control programs.
Use programming and naming standards.
Create a symbol library.
Commission a control program.
Use EIKON productivity tools.
Build a properties page.
Make major edits to an existing control program.
Create an advanced control program with a custom sequence of operation.
The EIKON II course has been developed for individuals that require advanced programming sequences to accomplish custom scenarios. Learners will use all the options within EIKON as well as the EquipmentBuilder tool.
Traditional Classroom
A live instructor will lead up to 12 students (course dependent) in hands-on exercises with minimal lecture in between. Using the situated learning techniques of the Kirkpatrick Model, this methodology fosters a collaborative learning environment where students are positioned to maximize knowledge retention. This course is a 2- or 3-day event depending on location.
Instructor-Led eLearning
A live instructor will lead students using video conferencing and remote access software. The student will have remote access to a training station to complete hands-on tasks, giving them a virtual classroom experience from many miles away. This course is hosted in the same 2-day timeframe and manner as the traditional classroom format.
EIKON fundamentals
Verify option settings
Save the control program
Place the microblocks
Connect microblocks with wires
Edit microblock properties
Simulate the control program
EIKON best practices & standards
Create a header section
Place input and output microblocks
Space and align microblocks
Add descriptive text
Connect microblocks and labels with wires
Reorder microblocks
Add section headers to the Edit Order list
Add expand/collapse sections on the Properties page
Align items on the Properties page
Real-world programming - Part 1
Create a .logicsymbol
Create a control program using EquipmentBuilder®
Decipher a control program
Modify a control program
EIKON tools
Info…
Find…
Import and Export Symbols
Edit Common Properties…
Palette…
Configure tools…
Suppress Logic and Remove Property Page Text
Properties for graphics…
Properties page
Format the chiller properties page
Real-world programming - Part 2
Field programming
Final project
To receive a certificate for this course student must be present for the entire course, complete all workshops and receive a grade of 70% on graded final.
After successfully completing this course, you will be able to use Automated Logic’s EIKON tool to quickly and efficiently:
Create basic control programs.
Use programming and naming standards.
Create a symbol library.
Commission a control program.
Use EIKON productivity tools.
Build a properties page.
Make major edits to an existing control program.
Create an advanced control program with a custom sequence of operation.
The EIKON II course has been developed for individuals that require advanced programming sequences to accomplish custom scenarios. Learners will use all the options within EIKON as well as the EquipmentBuilder tool.
Traditional Classroom
A live instructor will lead up to 12 students (course dependent) in hands-on exercises with minimal lecture in between. Using the situated learning techniques of the Kirkpatrick Model, this methodology fosters a collaborative learning environment where students are positioned to maximize knowledge retention. This course is a 2- or 3-day event depending on location.
Instructor-Led eLearning
A live instructor will lead students using video conferencing and remote access software. The student will have remote access to a training station to complete hands-on tasks, giving them a virtual classroom experience from many miles away. This course is hosted in the same 2-day timeframe and manner as the traditional classroom format.
EIKON fundamentals
Verify option settings
Save the control program
Place the microblocks
Connect microblocks with wires
Edit microblock properties
Simulate the control program
EIKON best practices & standards
Create a header section
Place input and output microblocks
Space and align microblocks
Add descriptive text
Connect microblocks and labels with wires
Reorder microblocks
Add section headers to the Edit Order list
Add expand/collapse sections on the Properties page
Align items on the Properties page
Real-world programming - Part 1
Create a .logicsymbol
Create a control program using EquipmentBuilder®
Decipher a control program
Modify a control program
EIKON tools
Info…
Find…
Import and Export Symbols
Edit Common Properties…
Palette…
Configure tools…
Suppress Logic and Remove Property Page Text
Properties for graphics…
Properties page
Format the chiller properties page
Real-world programming - Part 2
Field programming
Final project
To receive a certificate for this course student must be present for the entire course, complete all workshops and receive a grade of 70% on graded final.