TS2 Series Thermostats
This product is intended for international markets and is not for sale in USA/Canada.
Automated Logic’s TS2 Series communicating and non-communicating thermostats provide the flexibility to manage indoor climates in office buildings, hotels, and dorm rooms. The TS2 thermostats feature an intuitive touch key interface, designed to measure space temperature and precisely manage fan speed and operation modes. Available in configurations that support diverse application needs, equipment requirements, and ventilation strategies, they deliver reliable performance in both single-zone and multi-zone buildings.
Reduced Energy Costs with 7-day Scheduling: Optimizes energy consumption with 4-period, 7-day scheduling, and an economy (ECO) mode, leveraging the keycard S1/S2 input to automatically adjust setpoints for energy efficiency based on room occupancy.
Versatile Installation for Broad Application: Supports 2-pipe or 4-pipe fan coil units that can operate as standalone solutions or integrate with building automation systems, including the WebCTRL® BAS via the Modbus protocol.
Maximize Design Flexibility and System Integrity: Enables customized solutions using the S1/S2 input terminals, to support an analog input (for remote temperature sensing) or a dry contact input (for a 3rd party keycard or interlocks).
Enhanced Comfort and Intelligent Control: Provides an intuitive touch key interface with built in temperature sensor for effortless command of temperature, fan speed, and heating/cooling/ ventilation modes, with versatile 0–10V modulating valve and fan control.
Enhanced Reliability and Reduced Service Calls: Settings are battery backed and retained after power outages. Built-in diagnostics provide clear alarm/fault codes in case of sensor malfunction.
Improved Security and Policy Compliance: Prevents unauthorized access and tampering with button and menu lockout options.
Reduced Energy Costs with 7-day Scheduling: Optimizes energy consumption with 4-period, 7-day scheduling, and an economy (ECO) mode, leveraging the keycard S1/S2 input to automatically adjust setpoints for energy efficiency based on room occupancy.
Versatile Installation for Broad Application: Supports 2-pipe or 4-pipe fan coil units that can operate as standalone solutions or integrate with building automation systems, including the WebCTRL® BAS via the Modbus protocol.
Maximize Design Flexibility and System Integrity: Enables customized solutions using the S1/S2 input terminals, to support an analog input (for remote temperature sensing) or a dry contact input (for a 3rd party keycard or interlocks).
Enhanced Comfort and Intelligent Control: Provides an intuitive touch key interface with built in temperature sensor for effortless command of temperature, fan speed, and heating/cooling/ ventilation modes, with versatile 0–10V modulating valve and fan control.
Enhanced Reliability and Reduced Service Calls: Settings are battery backed and retained after power outages. Built-in diagnostics provide clear alarm/fault codes in case of sensor malfunction.
Improved Security and Policy Compliance: Prevents unauthorized access and tampering with button and menu lockout options.