Chiller Analytics
The IntelliSuite™ Chiller Analytics application provides predictive insights into the health of chillers. An intuitive web portal feeds key performance indicators (KPIs) via online dashboards, enabling your local Automated Logic representative to provide reports on chiller health. Proactive maintenance strategies can then be deployed, helping to prevent failure and optimize chiller performance.
Key Features and Benefits
- Utilize an authorized Automated Logic representative as your trusted advisor for chiller maintenance
- Maintain piece of mind that your chiller(s) are being proactively maintained
- Gain actionable insights from your Automated Logic representative directly through quarterly reports
- Receive predictive actionable insights for a single chiller or your entire portfolio of chillers
- Predictive actionable insights track equipment failure lifecycle in stages and provide recommendations at each stage – cause, impact, and how to correct
- Most tuning/fixes can be deployed remotely by the Automated Logic representative, without having to come on-site
- Helps improve chiller performance, increase reliability, and prevent failure
Sampling of Points Analyzed
- Leaving Chilled Water Temp
- Entering Chilled Water Temp
- Leaving Cond Water Temp
- Entering Cond Water Temp
- Percent Load Capacity
- Percent Load Current
- Actual Percent VFD
- Percentage Kilowatt
- Control Point
- Evaporator Approach
- Condenser Approach
- Saturated Suction Temp
- Comp Suction Temp
- Comp Discharge Temp
- Saturated Cond Temp
- Expansion Valve
- Chiller Run Status
- Utilize an authorized Automated Logic representative as your trusted advisor for chiller maintenance
- Maintain piece of mind that your chiller(s) are being proactively maintained
- Gain actionable insights from your Automated Logic representative directly through quarterly reports
- Receive predictive actionable insights for a single chiller or your entire portfolio of chillers
- Predictive actionable insights track equipment failure lifecycle in stages and provide recommendations at each stage – cause, impact, and how to correct
- Most tuning/fixes can be deployed remotely by the Automated Logic representative, without having to come on-site
- Helps improve chiller performance, increase reliability, and prevent failure
- Leaving Chilled Water Temp
- Entering Chilled Water Temp
- Leaving Cond Water Temp
- Entering Cond Water Temp
- Percent Load Capacity
- Percent Load Current
- Actual Percent VFD
- Percentage Kilowatt
- Control Point
- Evaporator Approach
- Condenser Approach
- Saturated Suction Temp
- Comp Suction Temp
- Comp Discharge Temp
- Saturated Cond Temp
- Expansion Valve
- Chiller Run Status

